H.T. Automatic Voltage Regulator (AVR)
Send Enquiry

 

H.T. Automatic Voltage Regulator (AVR)

RANGE: UP TO 15000 KVA IN 11 & 33 KV CLASS.

H.T. Automatic Voltage Stabilizers are used to get stabilized H.T. input voltage, irrespective of the voltage variations received from electricity supply authorities. Additionally, these stabilizers also prevent the transformer and other electrical equipment from getting overloaded. Wide voltage variation ranges are taken care continuously and in on load condition. The variations of more than ± 1% of the rated output voltage are sensed through solid state relay. This relay operates on 230 V, 110Ø supply and sends signals to the stabilizer's motor, which drives the roller mechanism in lower and higher direction to bring voltage to the rated output voltage within +- 1%. The Accuracy of +-1% may vary depending on the specific requirement of customer.

H.T. Automatic Servo Voltage Stabilizers have helical coils mounted on a conventional laminated core. Carbon rollers are assembled on a fibre glass carrier board and are traverse to the length of the coil track. The rollers are connected to the electric output terminals. Nearby the regulating coil, a number of compensating winding is connected in parallel, which are short circuited to reduce the effect of core-flux fringing. It also keeps the reactance of the regulator constant at any position of the rolling contact.

Application

These HT-Automatic Voltage Regulators are widely used in different industrial sectors for getting a stable input voltage.

 

Construction
  • Generally H. T. Automatic Voltage Regulator consist of two tanks to facilitate servicing of the moving parts of Rolling Contacts and other components in the regulator without disturbing the main tank containing Transformers
  • Isolates Sensitive Equipment's from Noisy Power Lines
  • Carbon rollers goes around the length of the coil track & are assembled on a fiber glass carrier board
  • The rollers are connected to the electric output terminals
  • Parallel connection of compensating winding near the regulating coil is done
  • The connection between the windings and regulating coils is short circuited so as to reduce the effect of core-flux fringing
  • It keeps the reactance of the regulator constant at any position of the rolling contact

 

Standard Specification :

 

Capacity
Up to 14000 KVA
No. of Phases
3 Phase
Frequency
50 Hz.
Voltage Range
11 KV/ 33 KV
Tapping
30% to +20%
Insulation
Class 'A'
Vector Group
Dyn 11
Duty Cycle
Continuous
Winding
Electrolytic Grade Copper Wound
Terminals
As per required

 

Standard Fittings

 

Rating & Diagram Plate
Earthing Terminals
Lifting Lugs
Thermometer Pocket
Oil Conservator with Drain Plug
Air Release Hole with Plug
Oil Level Indicator
Explosion Vent with Diaphragm
Top-Filter Valve
Inspection Cover
Silica Gel Breather
Drain-Cum-Bottom-Filter Valve
Cooling Radiators
Uni / Bi-Directional Rollers

 

Advantage
  • Utilization of the Distribution Transformer is to its full capacity as the H.T. AVR shares the load of the Transformer and the connected load
  • Losses are less as the incoming voltage either low or high is corrected at the initial stage only
  • Fluctuations in the H.T. Supply are not passed on to the Distribution Transformer
  • Installation Cost is less in comparison to L.T. Automatic Servo Voltage Stabilizer, for higher ratings
  • Single Unit of H.T. Automatic Servo Voltage Stabilizer can be connected to more than one Distribution Transformer
  • Economical for huge capacities like 2500 KVA and above or for wide voltage fluctuation range (eg. 8 KV – 13 KV, 28 KV – 36 KV etc.)
  • Can be placed anywhere on the feeder line
  • Motor fitting is external, so any change of the motor or motor shaft can be easily done without opening the top cover
  • Output Voltage of H.T. AVR remains constant at any connected Load and up to full load
  • Response time for Voltage correction is 20 micro seconds
  • Low replacement cost
  • 5% to 10% saving on energy consumption
  • Reduction in breakdown period of the machines
  • 100% capacity
  • On Load step-less voltage variation

 

Technical Advantage
  • Very Easy to maintain - No Specialize Manpower is required
  • Undistorted output characteristics ie. No wave from distortion
  • Moving parts on L.T. side and its mass is extremely low, only few lb-inch torque
  • Energy savings
  • High efficiency (about 99%) and minimum no load losses
  • Simplicity and flexibility of design
  • On load stepless voltage variation
  • Long service life
  • Impulse tested
  • Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs
  • Low replacement cost

 

Download PDF Download

 

Start Buying With Us.